Product Details:

Place of Origin: Zhejiang, China (Mainland)
Brand Name: Tengen
Certification: CCC CE
Model Number: CJX2

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: Standard package or according to customer's requirements
Delivery Time: 5-15 work days after confirm the payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 1800 Pieces per Month
Detailed Product Description
Type: AC Contactor Pole Numbers: 3P
Rated Operational Current: 380V:9A~620A Rated Insulation Voltage: 690V 1000V
Frequency: AC 50/60Hz Electricity Type: AC
Model: CJX2

CJX2 Series AC contactor insulation 690V 1000V Magnetic Mini electrical Contactors 9A~620A

 

Application

 

CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660v AC 50Hz or 60Hz, rated current up to 170A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactors, and star-delta starter. With the thermal relay, it is combined into the electromagnetic starter.

The technical function refers to standards GB14048.4, GB21518, IEC60947.

 

 

Features

 

• Adopt building block system to mount auxiliary contactor bolck, air delay auxiliary contactor, thermal overload relay and so on, which can be combined into multiple derived series product.

• Contactor has the adcantage of small volume , light, low consumption , high life , good safety.

• Main contactor below 32A has 1 N/C or 1 N/O , there is 1 N/C and 1 N/O above 40A.

Contactor can be assembled with F4F8 auxiliary contqct or Time-delay block.

• Contactor can not only use screw mounting, but also use 35mm [CJX-09~95], 75mm [CJX-40~95] and 2 x 35mm [CJX-115~170] international standard Din-rail mounting,

 

 

3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

 

Guidance For Selection Of Contactor

AC-3 Utilization category

Three phase asynchronous squirrel-cage motor breaking current under AC-3 Utilization category, It is motor rated running current.

 

3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

For example: asynchronous motor P = 5.5KW - Ue = 400V - le = 11A - Ic = le = 11A

                     or asynchronous motor P = 5.5KW - Ue = 415V - le = 11A - Ic = le = 11A

                     needs 3000000 operations.

According to above curves, the corresponding contactor model is CJX2-18.

 

Item

CJX2-09

CJX2-12

CJX2-18

CJX2-25

CJX2-32

CJX2-40

Rated operational current (A)

380V

AC-3

9

12

18

25

32

40

AC-4

3.5

5

7.7

8.5

12

18.5

660V

AC-3

7

9

12

18

21

34

AC-4

1.5

2

3.8

4.4

7.5

9

Conventional heating current (A)

20

20

32

40

50

60

Rated insulation voltage (V)

690

690

690

690

690

690

Power of controllable 3-phase squirrel cage motor (KW) AC-3

220V

2.2

3

4

5.5

7.5

11

380V

4

5.5

7.5

11

15

18.5

660V

5.5

7.5

10

15

18.5

30

Operational frequency (s/h)

Electric life

AC-3

1200

1200

1200

1200

600

600

AC-4

300

300

300

150

150

150

Mechanical life

3600

Electric life

(104 operations)

AC-3

100

100

100

100

80

AC-4

20

20

20

20

20

15

Mechanical life (104 operations)

1000

800

Matching fusing model

RT16-16

RT16-20

RT16-25

RT16-32

RT16-50

RT16-63

Average power consumption

(VA) 20℃

50Hz

Pick-up

76

110

230

Holding

9.4

11

32

Unit weight (KG)

3P+NO/NC

0.33

0.35

0.52

0.55

1.22

4P(4N/O)

-

-

1.32

4P(2N/O+2N/C)

1.37

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

CJX2-50

CJX2-65

CJX2-80

CJX2-95

CJX2-115

CJX2-150

Rated operational current (A)

380V

AC-3

50

65

80

95

115

150

AC-4

24

28

37

44

50

65

660V

AC-3

39

42

49

49

86

107

AC-4

12

14

17.3

21.3

25

32

Conventional heating current (A)

80

80

110

110

200

200

Rated insulation voltage (V)

690

690

690

690

1000

1000

Power of controllable 3-phase squirrel cage motor (KW) AC-3

220V

15

18.5

22

25

-

-

380V

22

30

37

45

55

75

660V

33

37

45

55

80

90

Operational frequency (s/h)

Electric life

AC-3

600

600

600

600

600

300

AC-4

150

150

150

150

300

300

Mechanical life

3600

3600

2400

2400

2400

2400

Electric life

(104 operations)

AC-3

60

60

60

60

40

40

AC-4

15

15

10

10

2

2

Mechanical life (104 operations)

800

800

600

600

300

300

Matching fusing model

RT16-63

RT16-80

RT16-100

RT16-125

RT16-160

RT16-200

Average power consumption

(VA) 20℃

50Hz

Pick-up

230

230

230

230

300

300

Holding

32

32

32

32

22

22

Unit weight (KG)

3P+NO/NC

1.22

1.22

1.42

1.42

2.08

2.08

4P(4N/O)

1.32

1.32

1.59

1.59

4P(2N/O+2N/C)

1.37

1.37

1.65

1.65

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

CJX2-170

CJX2-205

CJX2-245

CJX2-300

CJX2-410

CJX2-475

CJX2-620

Rated operational current (A)

380V

AC-3

170

205

245

300

410

475

620

AC-4

70

80

100

124

150

185

225

660V

AC-3

118

130

170

225

235

290

360

AC-4

35

40

47

60

72

85

100

Conventional heating current (A)

200

275

275

380

450

580

800

Rated insulation voltage (V)

1000

1000

1000

1000

1000

1000

1000

Power of controllable 3-phase squirrel cage motor (KW) AC-3

380V

90

90

110

160

200

250

335

660V

110

110

129

220

280

330

450

Operational frequency (s/h)

Electric life

AC-3

600

600

600

600

300

300

300

AC-4

150

150

150

150

150

150

150

Mechanical life

2400

2400

2400

2400

1200

1200

1200

Electric life

(104 operations)

AC-3

50

50

50

50

30

30

20

AC-4

10

10

10

10

8

8

5

Mechanical life (104 operations)

300

300

300

300

100

100

100

Matching fusing model

RT16-250

RT16-315

RT16-315

RT16-400

RT16-500

RT16-630

RT16-630

Average power consumption

(VA) 20℃

50Hz

Pick-up

300

800

800

1200

1200

1250

1650

Holding

22

55

55

13

20

24

22

Unit weight (KG)

3P

2.08

4.6

4.7

8.5

8.5

10.8

17.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

                                           Model and basic parameters of Auxiliary contact

 

Model

F4-11

F4-20

F4-02

F4-40

F4-31

F4-22

F4-13

F4-04

F8-11

F8-20

Number of auxiliary contact

NO

1

2

0

4

3

2

1

0

1

2

NC

1

0

2

0

1

2

3

4

1

0

 

Notes: Rated insulation voltage: 690V
           Control capacity: AC-15 360VA / DC-13 33W
           Conventional heating current: 10A
Operating characteristic:
           1. pick-up voltage: 86% Us ~ 110% Us
           2. drop-out voltage:20% Us ~ 75% Us

 

Item

CJX2-205

CJX2-245

CJX2-300

CJX2-410

CJX2-475

CJX2-620

Number of piece

1

1

1

2

2

2

Wire cross sectional(mm2)

150

185

240

150

240

240

Number of piece

2

2

2

2

5

2

Cu busbar (mm)

25×3

32×4

30×5

30×5

40×5

60×5

Bolt connection

M8

M10

M10

M10

M10

M12

 

3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A