    Product Details:

    Place of Origin: Zhejiang, China (Mainland)
    Brand Name: Tengen
    Certification: CCC CE
    Model Number: CJX2

    Payment & Shipping Terms:

    Minimum Order Quantity: 1
    Price: negotiable
    Packaging Details: Standard package or according to customer's requirements
    Delivery Time: 5-15 work days after confirm the payment
    Payment Terms: T/T, L/C, Western Union
    Supply Ability: 1800 Pieces per Month
    Detailed Product Description
    Type: AC Contactor Pole Numbers: 3P
    Rated Operational Current: 380V:9A~620A Rated Insulation Voltage: 690V 1000V
    Frequency: AC 50/60Hz Electricity Type: AC
    Model: CJX2

    CJX2 Series AC contactor insulation 690V 1000V Magnetic Mini electrical Contactors 9A~620A

     

    Application

     

    CJX2 series AC Contactor is suitable for using in the circuits the rated voltage up to 660v AC 50Hz or 60Hz, rated current up to 170A, for making & breaking, frequently starting & controlling the AC motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay contactor, mechanical interlocking contactors, and star-delta starter. With the thermal relay, it is combined into the electromagnetic starter.

    The technical function refers to standards GB14048.4, GB21518, IEC60947.

     

     

    Features

     

    • Adopt building block system to mount auxiliary contactor bolck, air delay auxiliary contactor, thermal overload relay and so on, which can be combined into multiple derived series product.

    • Contactor has the adcantage of small volume , light, low consumption , high life , good safety.

    • Main contactor below 32A has 1 N/C or 1 N/O , there is 1 N/C and 1 N/O above 40A.

    Contactor can be assembled with F4F8 auxiliary contqct or Time-delay block.

    • Contactor can not only use screw mounting, but also use 35mm [CJX-09~95], 75mm [CJX-40~95] and 2 x 35mm [CJX-115~170] international standard Din-rail mounting,

     

     

    3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

     

    Guidance For Selection Of Contactor

    AC-3 Utilization category

    Three phase asynchronous squirrel-cage motor breaking current under AC-3 Utilization category, It is motor rated running current.

     

    3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

    For example: asynchronous motor P = 5.5KW - Ue = 400V - le = 11A - Ic = le = 11A

                         or asynchronous motor P = 5.5KW - Ue = 415V - le = 11A - Ic = le = 11A

                         needs 3000000 operations.

    According to above curves, the corresponding contactor model is CJX2-18.

     

    Item

    CJX2-09

    CJX2-12

    CJX2-18

    CJX2-25

    CJX2-32

    CJX2-40

    Rated operational current (A)

    380V

    AC-3

    9

    12

    18

    25

    32

    40

    AC-4

    3.5

    5

    7.7

    8.5

    12

    18.5

    660V

    AC-3

    7

    9

    12

    18

    21

    34

    AC-4

    1.5

    2

    3.8

    4.4

    7.5

    9

    Conventional heating current (A)

    20

    20

    32

    40

    50

    60

    Rated insulation voltage (V)

    690

    690

    690

    690

    690

    690

    Power of controllable 3-phase squirrel cage motor (KW) AC-3

    220V

    2.2

    3

    4

    5.5

    7.5

    11

    380V

    4

    5.5

    7.5

    11

    15

    18.5

    660V

    5.5

    7.5

    10

    15

    18.5

    30

    Operational frequency (s/h)

    Electric life

    AC-3

    1200

    1200

    1200

    1200

    600

    600

    AC-4

    300

    300

    300

    150

    150

    150

    Mechanical life

    3600

    Electric life

    (104 operations)

    AC-3

    100

    100

    100

    100

    80

    AC-4

    20

    20

    20

    20

    20

    15

    Mechanical life (104 operations)

    1000

    800

    Matching fusing model

    RT16-16

    RT16-20

    RT16-25

    RT16-32

    RT16-50

    RT16-63

    Average power consumption

    (VA) 20℃

    50Hz

    Pick-up

    76

    110

    230

    Holding

    9.4

    11

    32

    Unit weight (KG)

    3P+NO/NC

    0.33

    0.35

    0.52

    0.55

    1.22

    4P(4N/O)

    -

    -

    1.32

    4P(2N/O+2N/C)

    1.37

     

     

     

     

     

     

     

     

     

     

     

     

     

    Item

    CJX2-50

    CJX2-65

    CJX2-80

    CJX2-95

    CJX2-115

    CJX2-150

    Rated operational current (A)

    380V

    AC-3

    50

    65

    80

    95

    115

    150

    AC-4

    24

    28

    37

    44

    50

    65

    660V

    AC-3

    39

    42

    49

    49

    86

    107

    AC-4

    12

    14

    17.3

    21.3

    25

    32

    Conventional heating current (A)

    80

    80

    110

    110

    200

    200

    Rated insulation voltage (V)

    690

    690

    690

    690

    1000

    1000

    Power of controllable 3-phase squirrel cage motor (KW) AC-3

    220V

    15

    18.5

    22

    25

    -

    -

    380V

    22

    30

    37

    45

    55

    75

    660V

    33

    37

    45

    55

    80

    90

    Operational frequency (s/h)

    Electric life

    AC-3

    600

    600

    600

    600

    600

    300

    AC-4

    150

    150

    150

    150

    300

    300

    Mechanical life

    3600

    3600

    2400

    2400

    2400

    2400

    Electric life

    (104 operations)

    AC-3

    60

    60

    60

    60

    40

    40

    AC-4

    15

    15

    10

    10

    2

    2

    Mechanical life (104 operations)

    800

    800

    600

    600

    300

    300

    Matching fusing model

    RT16-63

    RT16-80

    RT16-100

    RT16-125

    RT16-160

    RT16-200

    Average power consumption

    (VA) 20℃

    50Hz

    Pick-up

    230

    230

    230

    230

    300

    300

    Holding

    32

    32

    32

    32

    22

    22

    Unit weight (KG)

    3P+NO/NC

    1.22

    1.22

    1.42

    1.42

    2.08

    2.08

    4P(4N/O)

    1.32

    1.32

    1.59

    1.59

    4P(2N/O+2N/C)

    1.37

    1.37

    1.65

    1.65

     

     

     

     

     

     

     

     

     

     

     

     

     

    Item

    CJX2-170

    CJX2-205

    CJX2-245

    CJX2-300

    CJX2-410

    CJX2-475

    CJX2-620

    Rated operational current (A)

    380V

    AC-3

    170

    205

    245

    300

    410

    475

    620

    AC-4

    70

    80

    100

    124

    150

    185

    225

    660V

    AC-3

    118

    130

    170

    225

    235

    290

    360

    AC-4

    35

    40

    47

    60

    72

    85

    100

    Conventional heating current (A)

    200

    275

    275

    380

    450

    580

    800

    Rated insulation voltage (V)

    1000

    1000

    1000

    1000

    1000

    1000

    1000

    Power of controllable 3-phase squirrel cage motor (KW) AC-3

    380V

    90

    90

    110

    160

    200

    250

    335

    660V

    110

    110

    129

    220

    280

    330

    450

    Operational frequency (s/h)

    Electric life

    AC-3

    600

    600

    600

    600

    300

    300

    300

    AC-4

    150

    150

    150

    150

    150

    150

    150

    Mechanical life

    2400

    2400

    2400

    2400

    1200

    1200

    1200

    Electric life

    (104 operations)

    AC-3

    50

    50

    50

    50

    30

    30

    20

    AC-4

    10

    10

    10

    10

    8

    8

    5

    Mechanical life (104 operations)

    300

    300

    300

    300

    100

    100

    100

    Matching fusing model

    RT16-250

    RT16-315

    RT16-315

    RT16-400

    RT16-500

    RT16-630

    RT16-630

    Average power consumption

    (VA) 20℃

    50Hz

    Pick-up

    300

    800

    800

    1200

    1200

    1250

    1650

    Holding

    22

    55

    55

    13

    20

    24

    22

    Unit weight (KG)

    3P

    2.08

    4.6

    4.7

    8.5

    8.5

    10.8

    17.4

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

    3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

                                               Model and basic parameters of Auxiliary contact

     

    Model

    F4-11

    F4-20

    F4-02

    F4-40

    F4-31

    F4-22

    F4-13

    F4-04

    F8-11

    F8-20

    Number of auxiliary contact

    NO

    1

    2

    0

    4

    3

    2

    1

    0

    1

    2

    NC

    1

    0

    2

    0

    1

    2

    3

    4

    1

    0

     

    Notes: Rated insulation voltage: 690V
               Control capacity: AC-15 360VA / DC-13 33W
               Conventional heating current: 10A
    Operating characteristic:
               1. pick-up voltage: 86% Us ~ 110% Us
               2. drop-out voltage:20% Us ~ 75% Us

     

    Item

    CJX2-205

    CJX2-245

    CJX2-300

    CJX2-410

    CJX2-475

    CJX2-620

    Number of piece

    1

    1

    1

    2

    2

    2

    Wire cross sectional(mm2)

    150

    185

    240

    150

    240

    240

    Number of piece

    2

    2

    2

    2

    5

    2

    Cu busbar (mm)

    25×3

    32×4

    30×5

    30×5

    40×5

    60×5

    Bolt connection

    M8

    M10

    M10

    M10

    M10

    M12

     

    3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

    3 Pole AC Electrical Contactor 690V 1000V , Magnetic Contactor Switch 9A~620A

    Contact Details
    Tengen International Industrial Limited

    Contact Person: sales

    Send your inquiry directly to us (0 / 3000)

    Other Products