Product Details:

Place of Origin: Zhejiang, China (Mainland)
Brand Name: Tengen
Certification: CCC
Model Number: FN12-12(D)

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: negotiable
Packaging Details: Standard package or according to customer's requirements
Delivery Time: 5-15 work days after confirm the payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 8000 Pieces per Month
Detailed Product Description
Model Number: FN12-12(D) Type: High Voltage Load Break Switch
Rated Voltage: 12kV Rated Current Major Loop(A): 630A 100A
Frequancy: 50HZ Electrical Life: 1000000times
Lighting Impulse Resisting Voltage: 75/85 KV Poles Number: 3

FN12-12(D) Indoor High Voltage 12kV Load Break Switch

Application

 

It is a three phase H.V. switch equipment of 12KV, 50Hz for breaking or closing load current., no-load transformer cable charging current and closing short-circuit current. The load switch with earth switch can bear short-circuit current. It is made up of FN12-12D load switch and S()LAJ-12(XRNT()-10) H.V. current-limiting fuse box. It can break any current, load switch breaking working current and fuse box breaking short-circuit current, jointly breaking any current between short-circuit current. Meantime, fuse box make the switch off of with the striker.

 

Standard

 

a. GB3804-90 <<3-63KV AC H.V load switch>>.

b. GB16926-1997 <>(eqv, IEC62271-2002).

c. GB1995-89 <>.

 

 

Environmental conditions for operation

 

A. The ambient air temperature: Max.: +40 °C. Min: -10 °C.

B. The altitude ≤ 1000m.

C. The relative humidity of air. daily average ≤ 90%. monthly average ≤ 95%.

D. The ambient air should not be obviously polluted by corrosively or the flammability gas and gleam. etc.

E. Without frequent shake.

F. Environment degree: grade .

 

If requirements are not mentioned above, users can fix them with the manufacturer.

 

Model and Meaning

Safety High Voltage Load Switch Three Phase 12kV For Breaking / Losing Load CurrentSafety High Voltage Load Switch Three Phase 12kV For Breaking / Losing Load Current

 

 

Technical Parameter and Performances

 

No. Item Unit Parameter
FN12-12D/630-20 FN12-12D.R/100-31.5
1 Rated voltage kV 12
2 Rated frequency Hz 50
3 Reated current A 630 100
4 Lighting impulse resisting voltage kV 75/85
5 1min power frequency with stand voltage kV 42/48
6 Rated heat - stability current kA 20(4S)
7 Rated machine-stability current kA 50
8 Rated closing current (peak) kA 50  
9 Rated short-circuit breaking current kA   31.5
10 Rated transfer current kA   1.5
11 Max. breaking current kA 1.8
12 Breaking no-load transformer capacity Kva 1250
13 Rated cable charging current A 10
14 Rated power load current breaking times time >100
15 Switch-off time of rated power load current switch on-and-off S   >0.06
16 Earth switch heat-stability current kA 20(2S) 20(2S)
17 Earth switch heat-stability current (peak) kA 50 50
18 Motor operating power voltage V AC220,DC48

 

Contour and installation dimension

Safety High Voltage Load Switch Three Phase 12kV For Breaking / Losing Load Current

Safety High Voltage Load Switch Three Phase 12kV For Breaking / Losing Load CurrentSafety High Voltage Load Switch Three Phase 12kV For Breaking / Losing Load Current

Contact Details
Tengen International Industrial Limited

Contact Person: sales

Send your inquiry directly to us (0 / 3000)